Edan iM3 Vital Signs Monitor

$2,450.00 + GST

The EDAN iM3 is a newer release featuring an integrated cable/hose hanger and a touchscreen for ease-of-use

A wide range of accessories available.
Please allow 2 – 3 weeks for delivery.


SKU EDAN-iM3SP Categories , ,


Share
Description

EDAN iM3 Vital Signs Monitor

Edan_iM3_Brochure
EDAN_im3_user_manual

A newer look from Edan, the iM3 looks good!

Combining a stunning ultra-slim design with a large capacitive touch screen and a rich set of leading functions,
the Edan iM3 takes the lead and presents itself at the beginning of a new generation of vital signs monitors.

Bringing in full options of SpO2, NIBP and differentiated work modes, iM3 serves for both long-time monitoring
and spot-check applications.

– Full touchscreen
– Standard accessories include Large Adult/Adult/Small Adult NIBP cuffs and Sp02 Probe
– Spot-check and continual working modes with a unique alarm system to meet most clinical needs
– High-capability data storage
– Backlight control and standby mode for power saving
– User-friendly design provides convenient access to frequently used functions
– Quick Temp / Infrared Ear Temp is available as an additional attachment.

EDAN SpO2 Module

Measuring Range 0% to 100%
Resolution 1%
Data Update Period 1 s
Accuracy: Adult /Pediatric +/-2% (70% to 100% SpO2) Undefined (0% to 69% SpO2)
Accuracy: Neonate +/-3% (70% to 100% SpO2) Undefined (0% to 69% SpO2)
SpO2 Storage Inteval:  In round or spot-checking mode 30 S (default), 1 min, 2 mins, 5 mins Pulse Rate Measuring Range: 25 bpm to 300 bpm
Adjustable Range of Alarm Limits: 30 bpm to 300 bpm
Resolution 1 bpm ☆Accuracy +/-2 bpm
Sensor: Red Light (660+/-3) nm
Infrared Light (905+/-10) nm
Emitted Light Energy < 15 mW PI
Measuring Range 0-10, the invalid PI value is 0.
Resolution 1

EDAN NIBP Module

Technique: Oscillometry
Mode Manual, Auto, Continuous, Average
Measuring Interval in AUTO Mode (unit: minutes) 1/2/3/4/5/10/15/30/60/90/120/180/240/360/480
Continuous 5 min, the interval is 5 s
Measuring Type SYS, DIA, MAP, PR
Average measurement Interval (unit: minutes) 1/2/3/4/5
Average measurement times 3/5

Measuring Range:
Adult Mode SYS: 40 mmHg to 270 mmHg
Adult Mode DIA: 10 mmHg to 215 mmHg
Adult Mode MAP: 20 mmHg to 235 mmHg
Pediatric Mode SYS: 40 mmHg to 230 mmHg
Pediatric Mode DIA: 10 mmHg to 180 mmHg
Pediatric Mode MAP: 20 mmHg to 195 mmHg
Neonatal Mode SYS: 40 mmHg to 135 mmHg
Neonatal Mode DIA: 10 mmHg to 100 mmHg
Neonatal Mode MAP: 20 mmHg to 110 mmHg

Alarm Type SYS, DIA, MAP ☆
Cuff Pressure Measuring Range 0 mmHg to 300 mmHg Pressure Resolution 1 mmHg
Maximum Mean Error ±5 mmHg
Maximum Standard Deviation 8 mmHg
Maximum Measuring Period Adult/Pediatric 120 s Neonate 90 s
Typical Measuring Period 20 s to 35 s (depend on HR/motion disturbance)

Dual Independent Channel Overpressure Protection: Adult (297±3) mmHg
Dual Independent Channel Overpressure Protection: Pediatric (245±3) mmHg
Dual Independent Channel Overpressure Protection: Neonatal (147±3) mmHg

PR:
Measuring Range 40 bpm to 240 bpm
Accuracy ±3 bpm or 3.5%, whichever is greater
Pre-inflation Pressure: Adult Mode Default: 160 mmHg Range: 80/100/120/140/150/160/180/200/220/240 mmHg
Pre-inflation Pressure: Pediatric Mode Default: 140 mmHg Range: 80/100/120/140/150/160/180/200 mmHg Pre-inflation Pressure: Neonatal Mode Default: 100 mmHg Range: 60/70/80/100/120 mmHg

Additional information