Biolight E80 ECG Machine

$2,800.00

The E80 is the idel ECG Machine when a large touch-screen is required. The system also features interpretation
Please allow 3 – 4 weeks for delivery.


SKU BLT-E80 Categories ,

Biolight Meditech logo

Share
Description

Biolight E80 ECG Machine

Download Brochure:

https://medspares.co.nz/wp-content/uploads/2021/10/E80-new-catalogue.pdf

E80_new_catalogue.pdf

Biolight E80 ECG Machine Basic Secifications 

Ideal for flourescent lit rooms/clinics
12 Channel ECG machine
12.1″ TFT LCD Filding Touchscreen
Full Alpha Numeric Keyboard
Fixed Memory 800 groups, SD Card extrnsion
210 X 20M roll or Z-Fold Paper
Direct connect all in one cable (no expensive acquisition box)
Full interpretation with 140 different analysis reports

Biolight E80 ECG Machine Advanced Secifications

Size and Weight:
Size: 400mmÅ~330mmÅ~100mm(WÅ~HÅ~D)
Weight: ≤7kg

Display:
Type: 12.1″, 800×600 TFT LCD touch screen

Power Supply:
Input voltage: AC:100V~240V, 50Hz/60Hz
Input power: 100VA
Standard: Comply with IEC 60601-1 and IEC 60601-1-2

Battery
Type: Rechargeable lithium-ion battery
Rated Voltage: 11.1V
Capability: 4000mAH
Operating time: Used continuously for 4 hours (print 150 shares of cardiogram)
Indication of battery capability: On Screen

Input/Output Specification
Keyboard: Standard PC 104 (position)
Standard touch-screen connector (4 lines)
Network connector: RJ-45 (one) TCP/IP; upgrade, Web function
USB connector: 1 x USB Host Support hot-swap, external USB printer
1 x USB Device connects PC computer
SD card: 1 x Standard SD card

Data Storage
Fixed Memory: 800 groups of ECG data
Optional Memory: Flash, SD card or U disk
Storage mode: Background storage automatically
Storage format: PDF, DAT, Dicom, FDA-XML, JPEG

Recorder
Recording way: Thermal dot array
Horizontal resolution: 40 dots/mm
Vertical resolution: 8 dots/mm
Recording speed: 5 mm/s,6.25 mm/s,10 mm/s,12.5 mm/s,25 mm/s,50 mm/s, error:±3%
Record width: 215mm
Paper: 210mm/215mm×20m(reel )210mmÅ~140mmÅ~20m (Z type)
Paper type: Folded/Reel thermosenstive printing paper
Recording type: more than 10 kind of printing methods
(Auto:3×4,3×4+1R,3×4+3R,6×2,6×2+1R,12×1, 12×1_V6;Manual : 3 path, 6path, 12path, Rhythm: single-lead, three-leads , R-R: R-R)

Measure and Diagnosis of ECG Waveform
HR range: 30bpm -300bpm
HR precision: ±1bpm (10s average)
Coefficient error: ≤5%, 0.333
Measure info of ECG waveform: P time limit, PR interphase,QRS time limit, QT interphase,QTC interphase,
RV5swing, SV1swing, RV6swing, SV2swing, RV5+SV1swing, P axis,QRS axis , T axis
Diagnosis analyze: ≥140 kinds

Display of ECG Collection
Signal input: 12-lead, defibrillator-proof, Pacemaker pulse rejection
Degree of protection against electric shock: 4000V,
Type CF applied part
Electrode offset potential: ±600 mV d.c.
Response to frequency: 0.05Hz-200Hz
Baseline filter: On/Off
ECG filter: Off、25Hz,35Hz,45Hz
Lowpass filter: Off、75Hz,100Hz,150Hz、200Hz
Frequency filter: Off/On
Gain selection: 2.5,5,10,20,10/5,40,AGC (mm/mV)
Gain accuracy: ≤5%
Time base selection: 5 mm/s,6.25 mm/s,10 mm/s, 12.5 mm/s,25mm/s, 50mm/s
Input impedance: ≥50MΩ (10Hz)
Current of input loop: ≤15n A
Patients leakage current: ≤10 μ A
CMRR: ≥110 dB (with AC filter)
Time for response to wave displaying: ≤5s
Time for baseline recovered after switching leads: ≤1s
Defibrillator-proof: 5000V 360J
Standard complied with: IEC 60601-2-25

Environmental Specifications

Operating:
Temperature: 5℃~40℃
Relative humidity: 25%~95% (non condensing)
Atmospheric pressure: 700hPa~1060hPa
Temperature: -20℃~+55℃
Relative humidity: 25%~95% (non condensing)
Atmospheric pressure: 500hPa~1060 hPa

Additional information
Weight10 kg