EDAN SE-1201-PRO ECG
The EDAN SE-1201 Pro is a brand new release from EDAN, it features a sleek touchscreen interface loaded with powerfull software
Base confuguration:
12-channel ECG
8″ LCD display with full touch screen (fixed)
Latest SEMIP algorithm (Interpretation)
Build-in WiFi
Built-in rechargeable Lithium battery
Built-in thermal printer
Please allow 2 – 3 weeks for delivery.
Description
EDAN SE-1200-PRO ECG
ENG_ECG_SE-1200_Pro_SE-1201_Pro-Brochure
Let the machine work for you
All designed for the convenience of caregivers, the SE-1200 Pro and SE-1201 Pro enable easy-going workflows.
The devices will automatically record ECG once the signals are well sampled and present a timely reminder when the lead wires are misconnected, or the pacemaker is detected.
Self-adaptive Filter Technology
The innovative self-adaptive AC filter technology ensures more desirable ECG signal quality in real clinical setting, especially under extreme environment with unstable voltage.
On-screen Measurements & Diagnosis
Any waveform can be amplified and measured. Any report can be edited and confirmed.
Historic report can be selected and compared.
Powerful Connectivity Capability
The SE-1200/1201 Pro provides various network solutions to share the ECG data with IT system via LAN, Wi-Fi, Bluetooth or 4G.
EDAN SE-1201-Pro ECG Physical Specifications
Dimensions
298mm × 258mm × 82.5 mm
Weight 4.0kg (Excluding recorder paper and battery)
Display
10.0”, 1280×800 multicolor touch screen LCD Screen
The display can be flipped 25 degrees clockwise.
Power Supply
Mains Supply
Operating Voltage = 100V-240V
Operating Frequency = 50Hz/60Hz
Input Current = 0.9 0.4A
Internal Liion Battery Pack
Rated voltage = 14.8V
Rated capacity = 2,500 mAh or 5,000 mAh
Necessary Charge time: 3 hours or 6 hours
Recording
Recorder: Thermal dot matrix recorder
Printing Density: 8 dots per mm / 200 dots per inch (amplitude axes) 40 dots
per mm / 1000 dots per inch (time axes, @ 25 mm/s)
Recorder Paper:
Paper Speed: 5mm/s, 6.25mm/s, 10mm/s,
12.5mm/s, 25mm/s, 50mm/s
Folded thermal paper: 210mm×295mm×100pages (standard)
Folded thermal paper: 215mm×280mm×100pages (optional)
Folded thermal paper: 210mm×295mm×200pages (optional)
External Printer:
HP 1510, HP 1020P, HP 1112, HP 2132, HP DeskJet 4729
HP DeskJet 3638, HP M401, HP LaserJet P2035
HP 1010, HP Laserjet Pro M403D, HP LaserJet pro M202DW
HR Recognition
HR Range: 30 BPM ~300 BPM
Accuracy: ±1 BPM
ECG Unit
Leads: 9 or 12 standard leads
A/D Converter: 24bits
Time Constant: ≥5s
Sampling Frequency: 64,000 Hz/channel
Input Impedance: ≥100MΩ (10Hz)
Input Voltage Range”≤±5 mVpp
CMRR:
≥140dB (AC on)
≥123dB (AC off)
Acquisition Mode: 9 or 12 standard leads simultaneously
Resolution: 0.1192uV/LSB
Frequency Response: 0.01Hz ~ 350Hz (–3dB)
Gain: 1.25, 2.5, 5, 10, 20, 10/5 mm/mV, AGC, ±5%
Input Circuit Current: ≤0.01μA
Calibration Voltage: 1mV±2%
Pacemaker
Amplitude: ±500μV to ±700 mV
Width: 30μs to 2.0 ms
Sampling Frequency: 80,000 Hz, Rhythm Lead
Filter
AC Filter: Off/50Hz/60Hz
DFT Filter: 0.01Hz/0.05Hz/0.32Hz/0.67Hz
EMG Filter: Off/25Hz/35Hz/45Hz
LOWPASS Filter: 350Hz/300Hz/270Hz/150Hz/100Hz/75Hz
Data Transmission
Report Format: DAT, PDF, JPG, BMP, TIFF, SCP, FDA-XML, DICOM Encapsulated PDF
Data Transmission: Wi–Fi, Ethernet, 4G network
Data Management System:
SE-1515 Data Management System, bi-directional communication
HIS Connection: DICOM Worklist/DICOM Storage/HL7/GDT
Additional information
Weight | 10 kg |
---|